Run Monitor
Run Monitor is the third tab in the tuning workspace, showing progress in real time during a tuning run and letting you view the final results after the run ends.
Runtime Information
- Execution status and run state: which of Plan, Act, Settle, or Observe you are currently in, and whether the run is normal.
- Iteration records: each round's action (parameter setpoints), current objective values, current constraint values, and violation amounts.
- Optimization results: the optimal point and corresponding metrics given by the algorithm in this run.
When the service restarts, or the configuration has been updated but not yet run, a status notice bar appears at the top of the page explaining the difference between the current run and the latest configuration.
Write Out a Selected Action
After the tuning stops, you can write the parameters of a certain round's iteration directly to the field, with the following steps:
- Select a target iteration in the iteration records or optimization results.
- Select "Apply Selected Action," and after confirming, that set of parameters is written to the field device.
- Confirm the write takes effect through the read-back result or Time-Series Analysis.
This action is available only when all the following conditions are met; otherwise the interface gives the corresponding prompt:
- The tuning is stopped;
- An iteration is selected;
- No other tuning is running;
- No action is currently being submitted.
Applying a selected action directly changes field device parameters. Confirm the target values and adjustment range before writing.
Related Pages
View related data or perform related operations on the following pages:
View the field measurement point data corresponding to a certain round's action.
View field dataHistoryView the iteration tables of past runs or reload a certain run.
View the iteration tableManual ControlManually write parameters to a device and confirm by read-back.
Manual write and read-back