Skip to main content

Configure the Database Connection

Modify the time-series database connection in system configuration to connect the product to a standalone deployed IoTDB.

Configuration Steps​

  1. Sign in as an administrator and enter "System Configuration" in "System Management."
  2. Open the "Time-Series Database IoTDB" group under "Database."
  3. Fill in the address, port, user, and password of the standalone database, and confirm the timestamp precision matches the database server.
  4. After saving, restart the functions that read the time-series database as prompted on the page so the new connection takes effect.
  5. Verify: query curves in the time-series analysis interface and confirm data can be read normally; you can also run a simulation tuning once to confirm the data path is working.
warning

The standalone database's timestamp precision must be microseconds (us); for the configuration method, see Time-Series Database Deployment; inconsistent precision causes data read/write anomalies.

info

Connection changes take effect after restarting the related functions; after switching to the standalone database, the IoTDB installed locally during base deployment is no longer used.